Add to Cart
DC Switching Power Supply Single Output 50W
Description:
Low cost
Built-in EMI filter
Low output ripple&noise
Approvals: UL,CE
Protections: Over load/Short circuit
2 years warranty
Technical Data
Index Type |
S-50-5 |
S-50-12 |
S-50-15 |
S-50-24 |
DC Voltage |
5V |
12V |
15V |
24V |
Voltage Tolerance |
¡À2% |
¡À1% |
¡À1% |
¡À1% |
Rated Current |
10A |
4.2A |
3.4A |
2.1A |
CurrentRange |
10A |
4.2A |
3.4A |
2.1A |
Ripple&Noise(Max.) |
75mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
Line Regulation |
¡À0.5% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
Load Regulation |
¡À1% |
¡À0.5% |
¡À0.5% |
¡À0.5% |
Rated Power |
50W |
50.42W |
51W |
50.4W |
Efficiency |
71% |
78% |
78% |
82% |
Voltage Adjust Range |
+10 -5% |
¡À10% |
¡À10% |
¡À10% |
VoltageRange |
85¡«132VAC/170-264VACauto switch47¡«63Hz;240¡«370VDC |
|||
AC Current |
1.3A/115V 0.65A/230V |
|||
Inrush Current(Max.) |
cold start current¡¡18A/115V 36A/230V |
|||
Leakage Current |
<0.5mA/240VAC |
|||
Overload Protection |
105%¡«150%TYPE£ºCurrent limitation¡¡auto recovery |
|||
Over-voltage Protection |
...................... |
|||
Over-temperature Protection |
...................... |
|||
Temp.Coefficient |
¡À0.03%/¡æ(0¡«50¡æ) |
|||
Setup.Rise, Hold Time |
200ms, 100ms, 20ms |
|||
Vibration |
10¡«500Hz, 2G 10min, /11cycle, 60min, each axes |
|||
Withstand Voltage |
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC |
|||
Isolated Resistor |
I/P-O/P, I/P-FG, I/P-FG:500VDC/100M¦¸ |
|||
Working Temp.Humidity |
-10¡æ¡«+60¡æ(REFER TO CHARACTER CURVE), 20%¡«90RH |
|||
Storage Temp.Humidity |
-20¡æ¡«+85¡æ, 10%¡«95%RH |
|||
Dimension |
159¡Á97¡Á38mm |
|||
Weight |
0.5Kgs |
|||
Safety Standards |
UL1012 |
|||
EMC standards |
FCC PART15J class B |
Note£º
1.All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation:min&max voltage of the rated load.
5.load regulation:load from 0 to 100%.